Installation Instructions
574D
SINGLE ---PACKAGED AIR CONDITIONER GAS FURNACE
SYSTEM WITH PURONR (R ---410A) REFRIGERANT SINGLE AND
THREE PHASE
1---1/2---5 NOMINAL TONS (SIZES 018---060)
NOTE: Read the entire instruction manual before starting the
installation.
NOTE: Installer: Make sure the Owner’s Manual and Service
Instructions are left with the unit after installation.
TABLE OF CONTENTS
PAGE
SAFETY CONSIDERATIONS 1.........................
INTRODUCTION 2...................................
RECEIVING AND INSTALLATION 2--12.................
Check Equipment 2..................................
Identify Unit 2....................................
Inspect Shipment 2.................................
Provide Unit Support 2...............................
Roof Curb 2......................................
Slab Mount 2.....................................
Ground Mount 2..................................
Field Fabricate Ductwork 2............................
Provide Clearances 6.................................
Rig and Place Unit 6.................................
Inspection 6......................................
Use of Rigging Bracket 6............................
Connect Condensate Drain 8...........................
Install Flue Hood 8...................................
Install Gas Piping 9..................................
Install Duct Connections 9--10..........................
Configuring Units for Downflow (Vertical)
Discharge 9--10...................................
Install Electrical Connections 11........................
High--Voltage Connections 11........................
Special Procedures for 208--V Operation 11..............
Control Voltage Connections 11.......................
Heat Anticipator Setting 12..........................
Transformer Protection 12...........................
P R E -- S T A R T -- U P 1 2 -- 1 3................................
START--UP 13--19.....................................
Check for Refrigerant Leaks 13.........................
Start--Up Heating & Make Adjustments 13................
Check Heating Control 13...........................
Check Gas Input 13................................
Adjust Gas Input 14................................
Check Burner Flame 14.............................
Airflow and Temperature Rise 14......................
Heating Sequence of Operation 18.....................
Limit Switches 18.................................
Rollout Switch 18.................................
Start--Up Cooling & Make Adjustments 18................
Checking Cooling Control Operation 18................
Checking & Adjusting Refrigerant Charge 18............
Indoor Airflow and Airflow Adjustments 19.............
Cooling Sequence of Operation 19.....................
MAINTENANCE 23--26................................
Air Filter 23......................................
Indoor Blower and Motor 23.........................
Flue Gas Passageways 24............................
A99338
Fig. 1 -- Unit 574D
(Low NOx Model Available)
Induced Draft (Combustion Air) Blower 24..............
Limit Switch 24...................................
Burner Ignition 24.................................
Main B urners 24...................................
Outdoor Coil, Indoor Coil, & Condensate Drain Pan 24....
Outdoor Fan 25...................................
Electrical Controls and Wiring 25.....................
Refrigerant Circuit 26...............................
Gas Input 26......................................
Evaporator Airflow 26..............................
Puron Items 26....................................
TROUBLESHOOTING 27..............................
START-- UP CHECKLIST 27............................
SAFETY CONSIDERATIONS
Installation and servicing of this equipment can be hazardous due
to mechanical and electrical components. Only trained and
qualified personnel should install, repair, or service this equipment.
Untrained personnel can perform basic maintenance functions such
as cleaning and replacing air filters. All other operations must be
performed by trained service personnel. When working on this
equipment, observe precautions in the literature, on tags, and on
labels attached to or shipped with the unit and other safety
precautions that may apply.
Follow all safety codes. Installation must be in compliance with
local and national building codes. Wear safety glasses, protective
clothing, and work gloves. Have fire extinguisher available. Read
these instructions thoroughly and follow all warnings or cautions
included in literature and attached to the unit.
Seitenansicht 0
1 2 3 4 5 6 ... 31 32

Inhaltsverzeichnis

Seite 1 - Installation Instructions

1Installation Instructions574DSINGLE ---PACKAGED AIR CONDITIONER GAS FURNACESYSTEM WITH PURONR (R ---410A) REFRIGERANT SINGLE ANDTHREE PHASE1---1/2---

Seite 2 - RECEIVING AND INSTALLATION

102. Remove horizontal (metal) duct covers to access vertical(downflow) discharge duct knockouts in unit base.3. Use a screwdriver and hammer to remov

Seite 3

11Step 10 — Install Electrical ConnectionsELECTRICAL SHOCK HAZARDFailure to follow this warning could result in personalinjury or death.The unit cabin

Seite 4

12POWERSUPPLYFIELD-SUPPLIEDFUSED DISCONNECTHIGH VOLTAGEPOWER LEADS(SEE UNIT WIRINGLABEL)GRCONTROL BOXSPLICE BOXLOW-VOLTAGEPOWER LEADS(SEE UNITWIRING L

Seite 5 - Step 4 — Provide Clearances

13FIRE, EXPLOSION HAZARDFailure to follow this warning could result in personalinjury, death or property damage.Do not purge gas supply into the combu

Seite 6 - Step 5 — Rig and Place Unit

14CHECK GAS INPUTCheck gas input and manifold pressure after unit start-- up (SeeTable 3). If adjustment is required proceed as follows:S The rated ga

Seite 7

15A07230Fig. 15 -- 208/230-- 1-- 60 Wiring Diagram574D

Seite 8 - Step 7 — Install Flue Hood

16A07232Fig. 16 -- 208/230-- 3-- 60 Wiring Diagram574D

Seite 9 - Step 8 — Install Gas Piping

17A07231Fig. 17 -- 460 --3 --60 Wiring Diagram574D

Seite 10 - DUCT COVERS REMOVED

18Table 3 – Heating InputsHEATING INPUT(BTUH)NUMBEROFGAS SUPPLY PRESSURE (IN. WC)MANIFOLDPRESSURE(INWC)NUMBEROFORIFICESNatural{ Propane*{MANIFOLDPRESS

Seite 11 - STANDARD CONNECTION

19use mercury or small dial--type thermometers because they are notadequate for this type of measurement.UNIT DAMAGE HAZARDFailure to follow this caut

Seite 12 - PRE-- START-- UP

2Recognize safety information. This is the safety-- alert symbol.When you see this symbol on the unit and in instructions or manu-als, be alert to the

Seite 13 - MOTOR AND FAN HUB

20Table6–CoolingChargingChart75 (24) 85 (29) 95 (35) 105 (41) 115 (46)Pressure(psig)5 10152025Pressure(kPa)3 6 8 11 14018 13 (7.2) 14 (7.8) 15 (5.0) 1

Seite 14

21Table 8 Con’t—Dry Coil Air Delivery* -- Horizontal a nd Downflow Discharge --Unit 574D024--060 (Deduct 10% for 208 Volts)UnitHeating RiseRangeoF(°C)

Seite 15

22Table 8 Con’t—Dry Coil Air Delivery* -- Horizontal a nd Downflow Discharge --Unit 574D024--060 (Deduct 10% for 208 Volts)UnitHeating RiseRangeoF(°C)

Seite 16

23Table 9 – 574D Wet Coil Pressure DropUNITSIZESTANDARD CFM (S.C.F.M.)500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000018 0.

Seite 17

24housing, and slide motor and motor mount out ofhousing.2. Remove and clean blower wheel as follows:a. Ensure proper reassembly by marking wheel orie

Seite 18

25INDUCED DRAFT MOTOR MOUNTFLUECOLLECTORBOXBLOWERHOUSINGBURNERRACKMOUNTINGSCREWROLLOUTSWITCHIGNITION MODULEA05119Fig. 18 -- Blower Housing and Flue Co

Seite 19 - COOLING SEQUENCE OF OPERATION

26REFRIGERANT CIRCUITAnnually inspect all refrigerant tubing connections and the unitbase for oil accumulations. Detecting oil generally indicates are

Seite 20 - Table6–CoolingChargingChart

27Compressor OilThe compressor in this system uses a polyolester (POE) oil, Mobil3MAF POE. This oil is extremely hygroscopic, meaning it absorbswater

Seite 21

28PURONR (R-- 410A) QUICK REFERENCE GUIDES Puron refrigerant operates at 50--70 percent higher pressures than R--22. Be sure that servicing equipment

Seite 22

29Table 10 – Troubleshooting ChartSYMPTOM CAUSE REMEDYCompressor and condenser fan will not start.Power failure Call power companyFuse blown or circui

Seite 23 - MAINTENANCE

3REQUIRED CLEARANCE FOR OPERATION AND SERVICINGINCHES [mm]EVAP. COIL ACCESS SIDE...36.00 [914

Seite 24

30Table 11 – Troubleshooting Guide–HeatingSYMPTOM CAUSE REMEDYBurners will not igniteWater in gas line Drain. Install drip leg.No power to furnace Che

Seite 25 - OUTDOOR FAN

31START-UP CHECKLIST(Remove and Store in Job File)I. Preliminary InformationMODEL NO.:_________________________________SERIAL NO.:____________________

Seite 26

32Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.E2

Seite 27 - START--UP CHECKLIST

4REQUIRED CLEARANCE FOR OPERATION AND SERVICINGINCHES [mm]EVAP. COIL ACCESS SIDE...36.00 [914

Seite 28

5Gask et aroundouter edgeInsulateddeck panGask et aroundductS/AR/AHVAC unitbase*Gask etingouter flangeFlashing fieldsuppliedRoofing materialfield

Seite 29

6IMPORTANT: Do not restrict outdoor airflow. An air restrictionat either the outdoor--air inlet or the fan discharge may bedetrimental to compressor l

Seite 30

7Table 1 – Physical Data -- Unit 574DUNIT SIZE 018040 024040 024060 030040 030060 036060 036090 042060 042090NOMINAL CAPACITY (ton) 1 --- 1 / 2 2 2 2

Seite 31 - START-UP CHECKLIST

81234A07216DETAIL A A05161CORNER WEIGHTS (SMALL CABINET) CORNER WEIGHTS (LARGE CABINET)Unit018 024 030 036 Unit 042 048 060lb kg lb kg lb kg lb kg Tot

Seite 32 - Catalog No. II574D---03

93. Secure flue hood to flue panel by inserting a single screw onthe right side and the left side of the hood.Step 8 — Install Gas PipingThe gas suppl

Kommentare zu diesen Handbüchern

Keine Kommentare