Catalog No. PDS 340A.40.1
4-WAY MULTIPOISE
FIXED-CAPACITY
CONDENSING GAS FURNACE
340AAV
Sizes 040 thru 140
The model 340AAV Multipoise Condensing Furnace is specifi-
cally designed to meet the needs of the new construction
market. This high-efficiency furnace utilizes a unique 4-way
multipoise design and compact size to fit where other fur-
naces will not. The model 340AAV can be installed in any of 4
positions including horizontally in attics or crawlspaces, free-
ing space formerly used as a utility or furnace room. Except
for the 140 size, all sizes of the model 340AAV can be
installed in a manufactured (mobile) home when the optional
kit is used. With the exception of the 180 size, all sizes can be
installed with 2-pipe or 1-pipe venting. The 140 size can be
insalled only as a 2-pipe system. Sidewall or through-the-roof
venting options and the use of PVC pipe eliminate the need
for dedicated chimneys or chaseways to facilitate furnace
venting. Time-saving installation features yield a very cost
effective way to provide new home buyers with a high-effi-
ciency and high-quality home comfort system.
FEATURES
3-Pass Primary Heat Exchangers
—This design accelerates
heat transfer and extracts heat that conventional heat exchang-
ers waste up the flue. The primary heat exchanger is made of
aluminized steel for corrosion resistance.
Combustion Air and Ventilation
—The 340AAV advanced
design allows Schedule 40PVC, PVC-DWV, SDR-21 PVC,
SDR-26 PVC (not approved in Canada), ABS-DWV, or ABS-
F628 Schedule 40 pipe to bring outdoor air into the furnace for
combustion. The extracted heat lowers the temperature of the
combustion products to a point (typically below 115°F) that any
of the approved types of pipe can also be used for venting
combustion products outside the structure. The combustion-air
and vent pipes can terminate through a side wall or through the
roof when using 1 of our approved vent termination kits.
Flow-Through Secondary Heat Exchangers
—Each cell is
laminated with our patented Everlastic
TM
polypropylene for
greater resistance to corrosion. This breakthrough in heating
technology helps extend the life of the furnace for years of
dependable performance. The heat exchanger is positioned in
the furnace to extract additional heat from the combustion
products regardless of furnace orientation.
Perfect Light™ Igniter
—Bryant’s unique SiN igniter is not only
physically robust but it is also electrically robust. It is capable of
running at line voltage and does not require complex voltage
regulators as do other brands. This unique feature further
enhances the reliability of 340AAV gas furnace and continues
Bryant’s tradition of technology leadership and innovation in
providing a reliable and durable product.
Warranty
—Limited Lifetime Warranty on the heat exchangers
for the lifetime of original owner in single family residence; 20
years in other residential and commercial applications. 5 year
Limited Warranty on entire unit.
Control Center
—The printed-circuit board and all internal wir-
ing are factory installed. Convenient terminals permit quick-
connection of a thermostat and air conditioning control circuits.
Connections for a humidifier and air cleaner are also provided.
4-Way Multipoise Design
—Allows a model 340AAV to be
installed in an upflow, downflow, or horizontal orientation.
The model 340AAV is available in 12 heat/airflow combinations,
and when combined with the 4-way design, allows for 48 different
applications. Factory configured for upflow application, this furnace
can easily be made ready for downflow or horizontal installations.
Direct or Non-direct Venting
—The 340AAV can be installed
as a 1 pipe/Non-Direct vent or 2 pipe/Direct vent furnace
except the 140 size which can be installed as 2-pipe only. This
provides added flexibility to meet diverse installation needs.
Insulated Casing
—Foil-faced insulation in the heat exchanger
section cuts heat loss. The casing also has the required open-
ings for left- or right-side connection of gas, electric, drain, and
vent connections.
Certifications
—The 340AAV units are CSA (A.G.A./C.G.A.)
design certified for use with natural and propane gases, as well
as GAMA efficiency rating certified. The furnace is factory-
shipped for use with natural gas. A CSA (A.G.A./C.G.A.) listed
gas conversion kit is required to convert furnace for use with
propane gas. The model 340AAV meets California Air Quality
Management District emission requirements. Except for the
140 size unit, all 340AAV models can be installed in a manu-
factured (mobile) home when the optional kit is used, and in
elevations up to 10,000 ft (140 size unit limitation of 7,000 ft).
Quality Registration
—The 340AAV is engineered and manu-
factured under an ISO 9001 registered quality system.
A05086
Seitenansicht 0
1 2 3 4 5 6 ... 15 16

Inhaltsverzeichnis

Seite 1 - CONDENSING GAS FURNACE

Catalog No. PDS 340A.40.1 4-WAY MULTIPOISE FIXED-CAPACITYCONDENSING GAS FURNACE 340AAV Sizes 040 thru 140 The model 340AAV Multipoise Condensing Furn

Seite 2 - DIMENSIONS (In.)

—10— COMBUSTION-AIR AND VENT PIPING Direct-Vent/2-Pipe (All Sizes) and Non-Direct Vent/1-Pipe (Sizes 040 Through 120 Only) ApplicationsMAXIMUM ALLOW

Seite 3 - ISO 9001:2000

—11— MAXIMUM ALLOWABLE EXPOSED VENT PIPE LENGTH (FT) WITH AND WITHOUT INSULATIONIN WINTER DESIGN TEMPERATURE AMBIENT* * Pipe length (ft) specified fo

Seite 4

—12— ACCESSORIES SIDE FILTER RACK* DIMENSIONS (In.) * Dimension A will change accordingly as dimension D is lengthened or shortene

Seite 5 - SPECIFICATIONS

—13— AIR DELIVERY—CFM (With Filter)* * A filter is required for each return-air supply.• For horizontal and downflow applications, use “1 side or botto

Seite 6 - KGATW0601HSI

—14—COMBUSTION AIR PIPE(DIRECT VENT/2-PIPE APPLICATION)A/C COILOUTDOOR UNITVENT PIPEHUMIDIFIERGAS-FIREDWATER HEATERELECTRONICAIR CLEANERAIRFLOWFRONT

Seite 7

—15—COMBUSTION–AIR PIPEELECTRONICAIR CLEANERFURNACECONDENSATEDRAINREFRIGERATIONPIPINGAIR CONDITIONINGCOILAIRFLOWVENT PIPEFRONT OF FURNACEA05066DIRECT

Seite 8 - See notesat end of table

—16— SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICEUNIT MUST BE INSTALLED IN ACCORDANCEWITH INSTALLATION INSTRUCTIONSCancels: PDS 340M.40.12© 2005 B

Seite 9

—2—A05070NOTES: 1. Minimum return-air openings at furnace, based on metal duct. If flex duct is used,see flex duct manufacturerí s recommendations fo

Seite 10

—3—This forced air furnace is equipped for use with natural gas at altitudes 0 - 10,000 ft (0 - 3,050m), except 140 size Furnaces are only approved f

Seite 11

—4— Controls—Thermostats and Zoning Non-Programmable Thermostat Selection * Model HP and 2S thermostat must be field converted to air conditioner ope

Seite 12 - VENT/EXHAUST

—5— SPECIFICATIONS See notes on page 7. UNIT SIZE 024040 036040 024060 036060 048060 036080RATINGS AND PERFORMANCE Input Btuh* 40,000 40,000 60,000 6

Seite 13

—6— SPECIFICATIONS See notes on page 7. UNIT SIZE 048080 060080 048100 060100 060120 060140RATINGS AND PERFORMANCE Input Btuh* 80,000 80,000 100,000

Seite 14

—7— * Gas input ratings are certified for elevations to 2000 ft. For elevations above 2000 ft, reduce ratings 2% for each 1000 ft above sea level. In

Seite 15

—8— COMBUSTION-AIR AND VENT PIPING Direct-Vent/2-Pipe (All Sizes) and Non-Direct Vent/1-Pipe (Sizes 040 Through 120 Only) ApplicationsMAXIMUM ALLOWA

Seite 16

—9— COMBUSTION-AIR AND VENT PIPING Direct-Vent/2-Pipe (All Sizes) and Non-Direct Vent/1-Pipe (Sizes 040 Through 120 Only) ApplicationsMAXIMUM ALLOWA