21
complete itself. If, through some wiring error or failure in the HP, the signal on
the O line remains for longer than 15 minutes, the thermostat ignores it and
allows Y to be turned of f when it is satisfied.
If the B f unct i on is sel ec te d (using Option 10), the the r m ost at cannot sens e when a
defr ost occur s. As a res ult, i t ca nnot gua ra nt ee that de f rost cycles will run to
completion. If the thermostat becomes satisfied during a defrost, it will turn of f the
compressor . The HP will then complete its defrost starting with the next cycle.
OPERATIONAL AND CONNECTION INFORMATION
Rc/Rh Connections
For installations having a separate 24VAC transformer for heating and cooling,
the R connection can be separated into two connections, one for each
transformer. This allows isolation between the two transformers to be preserved.
To separate Rc from Rh, remove the factory supplied jumper between the Rc and
Rh terminals. The Rh terminal powers the W output. The Rc terminal powers the
Y, G and O outputs.
O/B Terminal -- On HP Thermostat Only
This terminal is normally connected to the reversing valve of the heat pump. It is
called O when the valve is energized in cooling and B when it is energized in
heating. Option 10 of the Configuration Options makes the O/B selection.
Timers
There are several timers which influence the thermostat’s operation:
If any of the timers listed below is preventing the equipment from turning on, the
display icons which show the equipment is operating will be flashing to indicate
a turn--on delay is present.