Residential H&V - 60Hz R22 & R410A - Geothermal Heat Pumps - Rev.: 21 Aug, 2007D
11
DIMENSIONS — HORIZONTAL GT-PG (50YE) SERIES
Right Return Straight Discharge
Front
N
P
Blower
Outlet
M
O
Legend
CAP=Control Access Panel
CSP=Compressor Service Panel
BSP=Blower Service Panel
ASP=Alternate Service Panel
Right Return
Front
Straight
Discharge
5
CSP
Back
Discharge
Condensate
3 / 4” IPT
H
Front-View
4
3
2
1
A
CAP
BSP
Right Return Right View
- Filter Rack Knife Edge
Air Coil
C
V
U
B
ASP
T
S
Front
P
Blower
Outlet
M
O
Left Return Straight Discharge
Front
BSP
LEFT RETURN RIGHT RETURN
Air Coil
CSP
Front
Left Return Left View
- Filter Rack Knife Edge
1.1 [27.9mm]
C
V
T
SU
B
Unit Hanger Detail
X
Y
Front
Z
Right Return Back Discharge
A
Air Coil Side
C
R
P
Blower
Outlet
Q
O
ASP
CSP
BSP
2’ [61cm] Service
Access
Front
Left Return
H
CSP
Condensate
3 / 4” IPT
ASP
2’ [61cm] Service
Access
Air Coil Side
O
A
C
Left Return Back Discharge
P
Blower
Outlet
Q
R
BSP
N
2’ [61cm] optional
service access
2’ [61cm] optional
service access
G
F
D
E
3.25
[82.6mm] 3.25
[82.6mm]
1.6 [40.6mm]
Model
XYZ
in. cm. in. cm. in. cm.
018 - 030 62.1 157.7 24.5 62.2 20.3 51.4
036 71.1 180.6 27.5 69.9 23.3 59.1
042, 048 76.1 193.3 27.5 69.9 23.3 59.1
060, 070 81.1 206 27.5 69.9 23.3 59.1
K
L
J
1.6 [40.6mm]
Power Supply
3 / 4” [19.1mm] Knockout
1 / 2” [12.7mm]
Knockout
Low Voltage
1 / 2” [12.7mm]
Knockout
5
Straight
Discharge
Back
Discharge
12345 J K L
A B C D E F G H Loop 1/2" cond 1/2" cond 3/4" cond M N O P Q R S T U V
HWG HWG Cond- Water Low Ext Power (LH rtrn) Supply Supply (RH rtrn) Return Return
In Out ensate IPT IPT Voltage Pump Supply Width Depth Depth Height
in. 22.4 62.2 19.3 2.1 10.0 13.9 16.9 0.6 3.6 6.1 8.6 3.6 2.0 12.5 15.5 3.6 2.0 33.8 16.2 2.3 1.5
cm. 56.8 158.0 48.9 5.2 25.4 35.2 42.9 1.5 9.2 15.6 21.9 9.3 5.1 31.8 39.4 9.2 5.2 85.8 41.0 5.8 3.9
in. 25.4 71.2 21.3 3.4 10.8 15.6 18.9 0.6 3.4 6.1 8.6 3.1 1.2 19.0 17.5 3.1 1.0 34.8 18.2 3.1 1.5
cm. 64.5 180.8 54.0 8.6 27.5 39.7 47.9 1.5 8.6 15.6 21.9 8.0 3.1 48.3 44.5 8.0 2.6 88.3 46.1 7.8 3.9
in. 25.4 76.2 21.3 3.4 10.8 15.6 18.9 0.6 3.6 6.1 8.6 3.1 1.2 19.0 17.5 3.1 1.0 39.8 18.2 3.1 1.5
cm. 64.5 193.5 54.0 8.6 27.5 39.7 47.9 1.5 9.2 15.6 21.9 8.0 3.1 48.3 44.5 8.0 2.6 101.0 46.1 7.8 3.9
in. 25.4 81.2 21.3 3.4 10.8 15.6 18.9 0.6 3.6 6.1 8.6 3.1 1.2 19.0 17.5 3.1 1.0 44.8 18.2 3.1 1.5
cm. 64.5 206.2 54.0 8.6 27.5 39.7 47.9 1.5 9.2 15.6 21.9 8.0 3.1 48.3 44.5 8.0 2.6 113.7 46.1 7.8 3.9
Condensate is stainless steel 3/4" IPT.
Rev. 02/25/05D
Unit shipped with deluxe duct collar/filter rack extending from unit 3" (7.6cm) and is suitable for duct connection.
Discharge flange factory installed.
Horizontal
duct flange installed (+/- 0.10 in, +/- 2.5mm)
Return Connection
std. deluxe filter rack (+/- 0.10 in, +/- 2.5mm)
Overall Cabinet
Water Connections Electrical Knockouts Discharge Connection
Model
HWG
Width Depth Height In Out
024 -
030
1" Swivel 1" Swivel
036 1" Swivel 1" Swivel
042 -
048
1" Swivel 1" Swivel
060 -
070
1" Swivel 1" Swivel
in. 22.4 62.2 19.3 2.1 10.0 13.9 16.9 0.6 3.6 6.1 8.6 5.0 6.8 10.4 9.3 5.0 2.1 28.1 17.3 2.2 1.0
cm. 56.8 158.0 48.9 5.2 25.4 35.2 42.9 1.5 9.2 15.6 21.9 12.7 17.3 26.4 23.6 12.7 5.3 71.4 43.9 5.6 2.5