23
FAQ- HOME STANDBY
equipped with 8 circuits, the 12/12 kW with 10
circuits and the 15/13 kW comes equipped with
12 circuits integrated in the transfer switch.
You can determine your BRYANT size
requirement by identifying what circuits from your
home's main distribution panel you wish to supply
with back-up power. Simply choose the circuit
from your home that you wish to provide with
BRYANT power and match it to a same amperage
circuit on the BRYANT transfer switch. A 15 Amp
circuit for your living room can be matched to a 15
Amp circuit on your BRYANT transfer switch and
emergency distribution panel.
Liquid-cooled: The only completely accurate way
is to have an electrician apply an amp meter to
the circuits or appliances that are intended to
operate under backup power. It is recommended
that the amp draw be measured as the appliance
“starts up” when that appliance uses an inductive
or resistive motor.
Q Why aluminum enclosures?
A In coastal communities, salt air can destroy steel in a
short period of time. Aluminum is corrosion resistant,
so it prolongs the life and look of the generator.
Q What do you do if the customer has 200 Amp
service in their home?
A It is always recommended that emergency circuits
be isolated into a sub panel with its own breakers.
That way there isn’t any possibility that the
generator will be overloaded and the system is
able to operate as intended truly automatic.